EA-IQT125-F10  - Rotork United States  Sales


Please Contact Us to Order to offer competitive prices and delivery time for Rotork - EA-IQT125-F10 Quarter turn electric actuator number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

BRAND Rotork
Product EA-IQT125-F10
Description Quarter turn electric actuator
Internal code ONR3858133
Custom code 85015100
Technical specification IQT (3rd Generation) IQT125 F10 [IP68] 380/3/50 (-30 +70 °C) 4x M25 303B0000 . • INGRESS PROTECTION: IP66/IP68 - 20 metres/10 days, double-sealed terminal compartment • TEMPERATURE: -30° C to 70° C (-22° F to 158° F) for Watertight, FM or CSA EP enclosures, -20° C to 70° C (-4° F to 158° F) for ATEX or IECEx enclosures • SERVICE/DUTY RATING: Class A (On/Off)/Class B (Inching), nominal 60 starts at a rate ≤ 600 starts/hour. 15 minute rated at nominal 33% of rated torque. • MOTOR SWITCHING & SPEED CONTROL: Solid state motor switching incorporating 25% to 100% motor speed control. • SYNCROPHASE: Auto Phase rotation correction and lost phase protection on three phase supplies. • LOCAL CONTROLS: Open/Close selector and padlockable Local/Stop/Remote selector (stop remains available for safety). • LOCAL INDICATION: Illuminated LCD position indicator (0.1% increments) with closed/open limit symbols, torque and other status data. 3 LED's; red-open/yellow-intermediate/green-closed (reversible), blinker and alarms configurable. • POSITION SENSOR: Absolute encoder provides continuous high resolution position measurement, fully maintained during manual operation and without power or battery support. • BATTERY SUPPORT: Battery is not required for position sensing but, supports LCD display, operation of indication relays, commissioning and data logging in the absence of mains power. • MOUNTING: Can be in any orientation, local indication and controls rotatable in 90° increments to suit • MANUAL OVERRIDE: Padlockable clutch lever, Handwheel clockwise to close, automatically disengages when motor starts, nonrotating during electric operation. • LUBRICATION: Gearcase oil filled for life. • TORQUE SWITCHES: Configurable - 40% to 100% of rated with bypass option for start of travel • COMMISSIONING: Non- intrusive setup of; travel limits (auto setup option), relays, alarms and other functions via Infrared/Bluetooth Setting Tool (one supplied with each order). Can be password protected. • MECHANICAL TRAVEL STOPS: Stop bolt adjustment allows +/-5% variation of travel at each end position. • DATA LOGGING AND ASSET MANAGEMENT: Date/time stamped logging and display of operational events/trends, motor starts and valve torque profiles. Valve/actuator/gearbox data can be stored and service alarms set. Battery supported when power off. Data download via Infrared/Bluetooth Setting Tool for upload to a PC and analysis via free InSight2 software. • TERMINALS: M5 power and M4 control terminals, screws and washers supplied. For ring tag conductors, power 16.0mm², controls 4.0mm² • CABLE ENTRIES: 4x M25 threaded cable entries (alternatively 0.75” NPT or PG16). Cable glands not included in our scope of supply. • PAINT FINISH: Polyester powder coating 100 micron nominal thickness. Colours: Housings/Covers - Grey (00-A-05), Handwheel/Hand Auto Lever – Black. . Wiring diagram 303B0000 is described in IQ/IQT Control and Monitoring publication (PUB002-041) and includes: • CONTROL SUPPLY: 20 – 60VDC/40 – 120VAC or actuator derived 24VDC • CONTROL INPUTS: 6 inputs for open, close, stop/maintain, ESD and interlock signals, 20 – 60VDC/40 – 120VAC • INDICATION CONTACTS: 4 volt-free (SPST) latching contacts (S1-S4), rated at 120VAC/30VDC, 5mA to 5A, each configurable NO or NC to signal one of the following; open/closed or intermediate positions, moving (continuous or pulsing), Handwheel operation, local selected, remote selected, open/close interlock active, ESD active, motor tripped on torque in mid travel/going open/going closed, valve jammed, loss of power/phase or control supply, battery low, internal failure detected, thermostat tripped, programmable service alarms. • MONITOR AND AVAILABILITY RELAY: Independent relay with volt-free changeover contact, rated at 120VAC/30VDC, 5mA to 5A. De-energises in case of; loss of power/phase or control supply, local control or local stop selected (can be excluded), motor thermostat tripped or detected internal failure • ANALOGUE CONTROL/FEEDBACK: Proportional control over whole or part of valve stroke 0 to 5/10/20/mA or volt ranges, internally powered 4-20mA output proportional to position (Folomatic/CPT). Configurable for open, close or stay-put on loss of signal. Incorporates user adjustable deadband (percentage of signal) and motion inhibit time (seconds) for restricting hunting or over modulation caused by a fluctuating control signal.

Other Category Brands